Validated Healthcare Directory
0.2.0 - CI Build United States of America flag

Validated Healthcare Directory, published by HL7 International - Patient Administration Work Group. This is not an authorized publication; it is the continuous build for version 0.2.0). This version is based on the current content of https://github.com/HL7/VhDir/ and changes regularly. See the Directory of published versions

CodeSystem: VhDir Validation Type Code System

Official URL: http://hl7.org/fhir/uv/vhdir/CodeSystem/validation Version: 0.2.0
Active as of 2018-02-21 Computable Name: VhDirValidationType

Copyright/Legal: Used by permission of HL7 International all rights reserved Creative Commons License

This code system contains codes for documenting the attributes of the FHIR resource Validation to reflect the business process of validating information in a Healthcare Directory.

This Code system is referenced in the content logical definition of the following value sets:

This case-sensitive code system http://hl7.org/fhir/uv/vhdir/CodeSystem/validation defines the following codes:

CodeDisplayDefinition
noneneeded None neededNo validation needed/planned for this resource or element.
initial InitialValidation is only needed after initial attestation. For elements that typically do not change such as 'medical school attended and graduation date'.
periodic PeriodicValidation is needed after initial attestation and on a periodic basis. E.g. elements that expire or may change such as licensure.
attested AttestedIndicates the element or resource has only been attested.
validated ValidatedIndicates the element or resource has been successfully validated.
inprocess InprocessIndicates the element or resource is currently being validated.
reqreval Required revalidationIndicates the element or resource has passed an expiration date and requires revalidation.
valfailed Valiation failedIndicates validation was attepted on an element or resource and that validation failed.
nothing NothingNo external validation is required.
single SingleIndicates the element or resource is validated against a single source.
multiple MultipleIndicates the element or resource may require validation against multiple sources, e.g. a practitioner participating in an insurance network.
editcheck Edit checkIndicates the element or resource is validated for format, range, presence, or other similar properties.
valueset ValuesetIndicates the element or resource is validated against a value set.
extsource External sourceIndicates the element or resource is validated against an external source.
standalone Stand aloneIndicates the element or resource is validated by itself and is unrelated to other elements or resources.
incontext In contextIndicates the element or resource is validated by the existence or value of another related element or resource.
fatal FatalA failure that is likely relevant to local workflow environments, considered sufficient to suspend the resource/element and one or more action has been taken.
warning WarningA failure that may be relevant to some local workflow environments, but in and of itself is not consider sufficient to suspend the resource/element. E.g. validating membership in an organization.
recordonly Record onlyA failure that may be relevant to some local workflow environments and will be documented but not result in notification or publication of the error.
noaction No actionA failure that is unlikely to be relevant to any local workflow environment.
manual ManualThe resource or element is validated manually.
portal PortalThe resource or element is validated via a portal into a source of valid data.
push PushData is sent (i.e. pushed) from a source of valid data to the Healthcare Directory
pull PullData is retrieved (i.e. pulled) from a source of valid data into the Healthcare Directory
successful SuccessfulThe validation process is complete and a determination made that the the attested data is true and accurate.
failed FailedThe validation process is complete and a determination made that the the attested data is not true or accurate.
undetermined UndeterminedThe validation process is complete and a determination could not be made that the the attested data is, or is not, true and accurate.
pushyes YesThe primary source validation can be achieved via a push of data from the source of that information.
pushno NoThe primary source validation cannot be achieved via a push of data from the source of that information.
pushundetermined UndeterminedIt is if undetermined if primary source validation can be achieved via a push of data from the source of that information.
specific Specific requested changesThe sender will send specific changes to the healthcare directory as determined by agreement.
any Any changesThe sender will send all changes to the healthcare directory.
sourcedef As defined by the source/senderThe sender will only send changes they have determined to be significant.
owner OwnerIndicates the element or resource was attested to by the individual who owned the data.
authrep Authorized representativeIndicates the element or resource was attested to by an individual who was designated to attest by the owner of the data.
authint Authorized intermediaryIndicates the element or resource was attested to by a system (intermediary) that was designated to attest by the owner of the data.
non-auth-src Non-authorized sourceIndicates the element or resource was attested to by an individual or system that was not designated to attest by the owner of the data.
licenseboard License BoardLicense Board
primaryed Primary EducationPrimary Education
continuinged Continuing EducationContinuing Education
postalservice Postal ServicePostal Service
relowner Relationship ownerRelationship owner
regauth Registration AuthorityRegistration Authority
legalsource Legal sourceLegal source
issuingsource Issuing sourceIssuing source
attester AttesterAttester