ValueSet Comparison between http://hl7.org/fhir/uv/ips/ValueSet/results-specimen-collection-method-uv-ips vs http://hl7.org/fhir/ValueSet/specimen-collection-method

Messages

ErrorValueSet.urlValues for url differ: 'http://hl7.org/fhir/uv/ips/ValueSet/results-specimen-collection-method-uv-ips' vs 'http://hl7.org/fhir/ValueSet/specimen-collection-method'
ErrorValueSet.versionValues for version differ: '2.0.0' vs '4.0.1'
InformationValueSet.nameValues for name differ: 'ResultsSpecimenCollectionMethodUvIps' vs 'FHIRSpecimenCollectionMethod'
InformationValueSet.titleValues for title differ: 'Results Specimen Collection Method - IPS' vs 'FHIR Specimen Collection Method'
InformationValueSet.statusValues for status differ: 'active' vs 'draft'
InformationValueSet.dateValues for date differ: '2025-10-03T15:47:44+00:00' vs '2019-11-01T09:29:23+11:00'
InformationValueSet.publisherValues for publisher differ: 'HL7 International / Patient Care' vs 'FHIR Project team'
InformationValueSet.copyrightValues for copyright differ: 'This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement' vs 'This resource includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these specifications must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomed-ct or info@snomed.org'
InformationValueSet.jurisdictionRemoved the item 'http://unstats.un.org/unsd/methods/m49/m49.htm#001'

Metadata

NameValueComments
.compose.inactive
    .compose.lockedDate
      .copyrightThis value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreementThis resource includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these specifications must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomed-ct or info@snomed.org
      • Values Differ
      .date2025-10-03T15:47:44+00:002019-11-01T09:29:23+11:00
      • Values Differ
      .descriptionIPS Specimen collection method codes value set. This value set includes codes from SNOMED CT®: all descendants or self of 129316008 \|Aspiration - action (qualifier value)\|; all descendants or self of 129314006 \|Biopsy - action (qualifier value)\|; all descendants or self of 129300006 \|Puncture - action (qualifier value)\|; all descendants or self of 129304002 \|Excision - action (qualifier value)\|; all descendants or self of 129323009 \|Scraping - action (qualifier value)\|; all descendants or self of 73416001 \|Urine specimen collection, clean catch (procedure)\|; all descendants or self of 225113003 \|Timed urine collection (procedure)\|; all descendants or self of 70777001 \|Urine specimen collection, catheterized (procedure)\|; all descendants or self of 386089008 \|Collection of coughed sputum (procedure)\|; all descendants or self of 278450005 \|Finger-prick sampling (procedure)\| SNOMED CT® ECL definition:\ \<\< 129316008 \|Aspiration - action (qualifier value)\| OR \<\< 129314006 \|Biopsy - action (qualifier value)\| OR \<\< 129300006 \|Puncture - action (qualifier value)\| OR \<\< 129304002 \|Excision - action (qualifier value)\| OR \<\< 129323009 \|Scraping - action (qualifier value)\| OR \<\< 73416001 \|Urine specimen collection, clean catch (procedure)\| OR \<\< 225113003 \|Timed urine collection (procedure)\| OR \<\< 70777001 \|Urine specimen collection, catheterized (procedure)\| OR \<\< 386089008 \|Collection of coughed sputum (procedure)\| OR \<\< 278450005 \|Finger-prick sampling (procedure)\| This example value set defines a set of codes that can be used to indicate the method by which a specimen was collected.
      • Values Differ
      .experimentalfalse
        .immutablefalse
        • Removed the item 'false'
        .jurisdiction
          ..jurisdiction[0]http://unstats.un.org/unsd/methods/m49/m49.htm#001
          • Removed the item 'http://unstats.un.org/unsd/methods/m49/m49.htm#001'
          .nameResultsSpecimenCollectionMethodUvIpsFHIRSpecimenCollectionMethod
          • Values Differ
          .publisherHL7 International / Patient CareFHIR Project team
          • Values Differ
          .purpose
            .statusactivedraft
            • Values Differ
            .titleResults Specimen Collection Method - IPSFHIR Specimen Collection Method
            • Values Differ
            .urlhttp://hl7.org/fhir/uv/ips/ValueSet/results-specimen-collection-method-uv-ipshttp://hl7.org/fhir/ValueSet/specimen-collection-method
            • Values Differ
            .version2.0.04.0.1
            • Values Differ

            Definition

            ItemPropertyValueComments
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Removed Include
            .includehttp://snomed.info/sct
            • Added Include

            Expansion

            Unable to generate expansion - see errors