US Core Implementation Guide
8.0.0-ballot - Ballot United States of America flag

US Core Implementation Guide, published by HL7 International / Cross-Group Projects. This guide is not an authorized publication; it is the continuous build for version 8.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/US-Core/ and changes regularly. See the Directory of published versions

: Serum Specimen Example - XML Representation

Page standards status: Informative

Raw xml | Download


<Specimen xmlns="http://hl7.org/fhir">
  <id value="specimen-example-serum"/>
  <meta>
    <extension url="http://hl7.org/fhir/StructureDefinition/instance-name">
      <valueString value="Serum Specimen Example"/>
    </extension>
    <extension
               url="http://hl7.org/fhir/StructureDefinition/instance-description">
      <valueMarkdown
                     value="This is a serum specimen example for the *US Core Specimen Profile*."/>
    </extension>
    <profile
             value="http://hl7.org/fhir/us/core/StructureDefinition/us-core-specimen"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Specimen specimen-example-serum</b></p><a name="specimen-example-serum"> </a><a name="hcspecimen-example-serum"> </a><a name="specimen-example-serum-en-US"> </a><p><b>accessionIdentifier</b>: <code>http://acme.com/labs/accession-ids</code>/20220927-00124</p><p><b>type</b>: <span title="Codes:{http://snomed.info/sct 119364003}, {http://terminology.hl7.org/CodeSystem/v2-0487 SER}">Serum sample</span></p><p><b>subject</b>: <a href="Patient-example.html">Amy V. Baxter  Female, DoB: 1987-02-20 ( Medical Record Number: 1032702 (use: usual, ))</a></p><h3>Collections</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Collected[x]</b></td></tr><tr><td style="display: none">*</td><td>2022-09-27 18:07:12+0000</td></tr></table><h3>Containers</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Type</b></td></tr><tr><td style="display: none">*</td><td><span title="Codes:">Serum Separator Tube</span></td></tr></table></div>
  </text>
  <accessionIdentifier>
    <system value="http://acme.com/labs/accession-ids"/>
    <value value="20220927-00124"/>
  </accessionIdentifier>
  <type>
    <coding>
      <system value="http://snomed.info/sct"/>
      <version value="http://snomed.info/sct/731000124108"/>
      <code value="119364003"/>
      <display value="Serum sample"/>
    </coding>
    <coding>
      <system value="http://terminology.hl7.org/CodeSystem/v2-0487"/>
      <code value="SER"/>
      <display value="Serum"/>
    </coding>
  </type>
  <subject>🔗 
    <reference value="Patient/example"/>
  </subject>
  <collection>
    <collectedDateTime value="2022-09-27T18:07:12Z"/>
  </collection>
  <container>
    <type>
      <text value="Serum Separator Tube"/>
    </type>
  </container>
</Specimen>