US Core Implementation Guide, published by HL7 International / Cross-Group Projects. This guide is not an authorized publication; it is the continuous build for version 8.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/US-Core/ and changes regularly. See the Directory of published versions
Page standards status: Informative |
{
"resourceType" : "Observation",
"id" : "satO2-fiO2",
"meta" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/instance-name",
"valueString" : "Observation SatO2 FiO2 Example"
},
{
"url" : "http://hl7.org/fhir/StructureDefinition/instance-description",
"valueMarkdown" : "This is a observation satO2 fiO2 example for the *US Core Pulse Oximetry Profile* representing a spO2 value with a for a patient on 6 l/min of O2 suppplemental oxygen."
}
],
"profile" : [
🔗 "http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Observation satO2-fiO2</b></p><a name=\"satO2-fiO2\"> </a><a name=\"hcsatO2-fiO2\"> </a><a name=\"satO2-fiO2-en-US\"> </a><p><b>identifier</b>: <code>http://goodcare.org/observation/id</code>/o1223435-10</p><p><b>status</b>: Final</p><p><b>category</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/observation-category vital-signs}\">Vital Signs</span></p><p><b>code</b>: <span title=\"Codes:{http://loinc.org 2708-6}, {http://loinc.org 59408-5}, {urn:iso:std:iso:11073:10101 150456}\">Oxygen saturation in Arterial blood</span></p><p><b>subject</b>: <a href=\"Patient-example.html\">Amy V. Baxter Female, DoB: 1987-02-20 ( Medical Record Number:\u00a01032702\u00a0(use:\u00a0usual,\u00a0))</a></p><p><b>effective</b>: 2014-12-05 09:30:10+0100</p><p><b>performer</b>: <a href=\"Practitioner-practitioner-1.html\">Dr Ronald Bone</a></p><p><b>value</b>: 95.0 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code% = '%')</span></p><p><b>interpretation</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation N}\">Normal</span></p><p><b>device</b>: Acme Pulse Oximeter 2000</p><h3>ReferenceRanges</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td style=\"display: none\">*</td><td>90.0 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code% = '%')</span></td><td>99.0 %<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM code% = '%')</span></td></tr></table><h3>Components</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Code</b></td><td><b>Value[x]</b></td></tr><tr><td style=\"display: none\">*</td><td><span title=\"Codes:{http://loinc.org 3151-8}\">Inhaled oxygen flow rate</span></td><td>6.0 liters/min<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeL/min = 'L/min')</span></td></tr></table></div>"
},
"identifier" : [
{
"system" : "http://goodcare.org/observation/id",
"value" : "o1223435-10"
}
],
"status" : "final",
"category" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/observation-category",
"code" : "vital-signs",
"display" : "Vital Signs"
}
],
"text" : "Vital Signs"
}
],
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "2708-6",
"display" : "Oxygen saturation in Arterial blood"
},
{
"system" : "http://loinc.org",
"code" : "59408-5",
"display" : "Oxygen saturation in Arterial blood by Pulse oximetry"
},
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "150456",
"display" : "MDC_PULS_OXIM_SAT_O2"
}
]
},
"subject" : {
🔗 "reference" : "Patient/example"
},
"effectiveDateTime" : "2014-12-05T09:30:10+01:00",
"performer" : [
{
🔗 "reference" : "Practitioner/practitioner-1",
"display" : "Dr Ronald Bone"
}
],
"valueQuantity" : {
"value" : 95.0,
"unit" : "%",
"system" : "http://unitsofmeasure.org",
"code" : "%"
},
"interpretation" : [
{
"coding" : [
{
"system" : "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
"code" : "N",
"display" : "Normal"
}
],
"text" : "Normal"
}
],
"device" : {
"display" : "Acme Pulse Oximeter 2000"
},
"referenceRange" : [
{
"low" : {
"value" : 90.0,
"unit" : "%",
"system" : "http://unitsofmeasure.org",
"code" : "%"
},
"high" : {
"value" : 99.0,
"unit" : "%",
"system" : "http://unitsofmeasure.org",
"code" : "%"
}
}
],
"component" : [
{
"code" : {
"coding" : [
{
"system" : "http://loinc.org",
"code" : "3151-8",
"display" : "Inhaled oxygen flow rate"
}
],
"text" : "Inhaled oxygen flow rate"
},
"valueQuantity" : {
"value" : 6.0,
"unit" : "liters/min",
"system" : "http://unitsofmeasure.org",
"code" : "L/min"
}
}
]
}