US Core Implementation Guide, published by HL7 International / Cross-Group Projects. This guide is not an authorized publication; it is the continuous build for version 8.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/US-Core/ and changes regularly. See the Directory of published versions
Page standards status: Informative |
<Observation xmlns="http://hl7.org/fhir">
<id value="qrs-dur-ekg-lead"/>
<meta>
<extension url="http://hl7.org/fhir/StructureDefinition/instance-name">
<valueString value="QRS dur {EKG lead} Example"/>
</extension>
<extension
url="http://hl7.org/fhir/StructureDefinition/instance-description">
<valueMarkdown
value="This is a QRS dur {EKG lead} Example for the *Clinical Test Result Observation Profile*."/>
</extension>
<profile
value="http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Observation qrs-dur-ekg-lead</b></p><a name="qrs-dur-ekg-lead"> </a><a name="hcqrs-dur-ekg-lead"> </a><a name="qrs-dur-ekg-lead-en-US"> </a><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category procedure}">Procedure</span></p><p><b>code</b>: <span title="Codes:{http://loinc.org 44973-6}">QRS dur {EKG lead}</span></p><p><b>subject</b>: <a href="Patient-example.html">Amy Shaw</a></p><p><b>encounter</b>: Cardiology Consult</p><p><b>effective</b>: 2021-11-10 16:48:57-0800</p><p><b>performer</b>: <a href="Practitioner-practitioner-1.html">Dr Ronald Bone</a></p><p><b>value</b>: 60.0 ms<span style="background: LightGoldenRodYellow"> (Details: UCUM codems = 'ms')</span></p></div>
</text>
<status value="final"/>
<category>
<coding>
<system
value="http://terminology.hl7.org/CodeSystem/observation-category"/>
<code value="procedure"/>
<display value="Procedure"/>
</coding>
<text value="Procedure"/>
</category>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="44973-6"/>
<display value="QRS dur {EKG lead}"/>
</coding>
<text value="QRS dur {EKG lead}"/>
</code>
<subject>🔗
<reference value="Patient/example"/>
<display value="Amy Shaw"/>
</subject>
<encounter>
<display value="Cardiology Consult"/>
</encounter>
<effectiveDateTime value="2021-11-10T16:48:57.246958-08:00"/>
<performer>🔗
<reference value="Practitioner/practitioner-1"/>
<display value="Dr Ronald Bone"/>
</performer>
<valueQuantity>
<value value="60.0"/>
<unit value="ms"/>
<system value="http://unitsofmeasure.org"/>
<code value="ms"/>
</valueQuantity>
</Observation>