<Requirements xmlns="http://hl7.org/fhir"><id value="example2"/><extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"><valueCode value="fhir"/></extension><url value="http://hl7.org/fhir/Requirements/example2"/><identifier><system value="urn:ietf:rfc:3986"/><value value="urn:oid:2.16.840.1.113883.4.642.18.2"/></identifier><name value="ExampleRequirements2"/><title value="Example Requirements Set 2"/><status value="active"/><date value="2021-11-02T14:31:30.239Z"/><publisher value="HL7 International / FHIR Infrastructure"/><contact><telecom><system value="url"/><value value="http://www.hl7.org/Special/committees/fiwg"/></telecom></contact><description value="Example Requirements Set 2"/><derivedFrom value="http://hl7.org/fhir/Requirements/example1"/><actor><reference value="http://hl7.org/fhir/ActorDefinition/server"/></actor><statement><key value="44595579-fa13-42a5-bd24-0515cde96963"/><label value="requirement-B1"/><conformance value="SHOULD"/><requirement value="Operations based on the SNOMED-CT should use the current version within 24 hours of each release"/><derivedFrom><reference value="http://hl7.org/fhir/Requirements/example1"/><key value="req-1"/></derivedFrom><source><display value="Lloyd Mackenzie"/></source></statement><statement><key value="46f77dcd-d51e-4738-b61f-22506d0cb0ac"/><label value="requirement-2/a"/><conformance value="SHALL"/><requirement value="ValueSet expansion and validation SHALL have the same result whether or not underlying CodeSystem resources have relationships represented explicitly as properties or implicitly using the CodeSystem resource hierarchy"/><source><display value="Robert Hausam"/></source></statement></Requirements>