{"conformsTo":[{"specification":{"coding":[{"code":"528388","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_DEV_SPEC_PROFILE_PULS_OXIM: Pulse Oximeter"},"version":"1"}],"deviceVersion":[{"type":{"coding":[{"code":"531976","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_ID_PROD_SPEC_FW: Firmware revision"},"value":"0.9C"},{"type":{"coding":[{"code":"532352","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_REG_CERT_DATA_CONTINUA_VERSION: Continua version"},"value":"1.0"}],"id":"Nonin20601PulseOx","identifier":[{"system":"urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680","type":{"coding":[{"code":"SYSID","display":"System Identifier","system":"http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"}]},"value":"00-1C-05-04-00-00-78-25"},{"system":"http://hl7.org/fhir/sid/eui-48","type":{"coding":[{"code":"BTMAC","display":"Bluetooth Address","system":"http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"}]},"value":"00-1C-05-00-78-25"}],"manufacturer":"Nonin Medical, Inc.","modelNumber":"Model 3150","name":[{"type":{"coding":[{"code":"user-friendly-name","system":"http://hl7.org/fhir/device-nametype"}]},"value":"Nonin_Medical_Inc._323552"}],"property":[{"type":{"coding":[{"code":"532353","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST: Continua certified device list"},"valueCodeableConcept":{"coding":[{"code":"4","system":"http://terminology.hl7.org/CodeSystem/ContinuaPAN"}]}},{"type":{"coding":[{"code":"532354.0","system":"http://terminology.hl7.org/CodeSystem/ASN1ToHL7"}],"text":"regulation-status"},"valueCodeableConcept":{"coding":[{"code":"N","system":"http://terminology.hl7.org/CodeSystem/v2-0136"}],"text":"Device is Regulated"}},{"type":{"coding":[{"code":"68220","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_TIME_SYNC_PROTOCOL: Time synchronization protocol"},"valueCodeableConcept":{"coding":[{"code":"532224","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_TIME_SYNC_NONE: No time synchronization"}},{"type":{"coding":[{"code":"68219.0","system":"http://terminology.hl7.org/CodeSystem/ASN1ToHL7"}],"text":"mds-time-capab-real-time-clock"},"valueCodeableConcept":{"coding":[{"code":"Y","system":"http://terminology.hl7.org/CodeSystem/v2-0136"}],"text":"real time clock supported"}},{"type":{"coding":[{"code":"68219.2","system":"http://terminology.hl7.org/CodeSystem/ASN1ToHL7"}],"text":"mds-time-capab-set-clock"},"valueCodeableConcept":{"coding":[{"code":"Y","system":"http://terminology.hl7.org/CodeSystem/v2-0136"}],"text":"setting the time supported"}},{"type":{"coding":[{"code":"68219.2","system":"http://terminology.hl7.org/CodeSystem/ASN1ToHL7"}],"text":"mds-time-capab-relative-time"},"valueCodeableConcept":{"coding":[{"code":"Y","system":"http://terminology.hl7.org/CodeSystem/v2-0136"}],"text":"relative time supported"}},{"type":{"coding":[{"code":"68222","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_TIME_RES_ABS: Resolution of absolute time clock"},"valueQuantity":{"code":"us","system":"http://unitsofmeasure.org","value":1000000}},{"type":{"coding":[{"code":"68222","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_TIME_RES_REL: Resolution of relative time clock"},"valueQuantity":{"code":"us","system":"http://unitsofmeasure.org","value":1000000}}],"resourceType":"Device","serialNumber":"0400007825","type":[{"coding":[{"code":"65573","display":"MDC_MOC_VMS_MDS_SIMP","system":"urn:iso:std:iso:11073:10101"}],"text":"MDC_MOC_VMS_MDS_SIMP: Personal Health Device"}],"udiCarrier":[{"carrierHRF":"(01)120343001125(21)0400007825","deviceIdentifier":"120343001125","entryType":"unknown","issuer":"http://hl7.org/fhir/NamingSystem/gs1-di","jurisdiction":"http://hl7.org/fhir/NamingSystem/fda-udi"}]}