<Bundle xmlns="http://hl7.org/fhir"><id value="example-observation-device-flowratemetric"/><type value="collection"/><entry><fullUrl value="http://hl7.org/fhir/Observation/example-observation-device-flowratemetric"/><resource><Observation><id value="example-observation-device-flowratemetric"/><text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Observation example-observation-device-flowratemetric</b></p><a name="example-observation-device-flowratemetric"> </a><a name="hcexample-observation-device-flowratemetric"> </a><p><b>identifier</b>: <code>http://goodcare.org/observation/id</code>/1191144-10</p><p><b>status</b>: Final</p><p><b>code</b>: <span title="Codes:{http://loinc.org 8977-1}">Fluid intake intravascular 8 hour</span></p><p><b>subject</b>: <a href="broken-link.html">Device/example-IV-pump</a></p><p><b>focus</b>: <a href="broken-link.html">DeviceMetric/example-iv-pump-flowratemetric</a></p><p><b>effective</b>: 2024-12-05T09:30:10+01:00</p><p><b>value</b>: 150 milliliter per 8 hour<span style="background: LightGoldenRodYellow"> (Details: UCUM  codemL/(8.h) = 'mL/(8.h)')</span></p><p><b>device</b>: <a href="broken-link.html">Device/example-IV-pump</a></p></div></text><identifier><system value="http://goodcare.org/observation/id"/><value value="1191144-10"/></identifier><status value="final"/><code><coding><system value="http://loinc.org"/><code value="8977-1"/><display value="Fluid intake intravascular 8 hour"/></coding></code><subject><reference value="Device/example-IV-pump"/></subject><focus><reference value="DeviceMetric/example-iv-pump-flowratemetric"/></focus><effectiveDateTime value="2024-12-05T09:30:10+01:00"/><valueQuantity><value value="150"/><unit value="milliliter per 8 hour"/><system value="http://unitsofmeasure.org"/><code value="mL/(8.h)"/></valueQuantity><device><reference value="Device/example-IV-pump"/></device></Observation></resource></entry><entry><fullUrl value="http://hl7.org/fhir/DeviceAssociation/example-device-patient-association"/><resource><DeviceAssociation><id value="example-device-patient-association"/><text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: DeviceAssociation example-device-patient-association</b></p><a name="example-device-patient-association"> </a><a name="hcexample-device-patient-association"> </a><p><b>device</b>: <a href="broken-link.html">Device/example-IV-pump</a></p><p><b>status</b>: Active</p><p><b>associationStatus</b>: <span title="Codes:{http://hl7.org/fhir/CodeSystem/deviceassociation-association-status attached}">Attached</span></p><p><b>subject</b>: <a href="patient-example-a.html">Donald Duck</a></p></div></text><device><reference value="Device/example-IV-pump"/></device><status value="active"/><associationStatus><coding><system value="http://hl7.org/fhir/CodeSystem/deviceassociation-association-status"/><code value="attached"/><display value="Attached"/></coding></associationStatus><subject><reference value="Patient/pat1"/><display value="Donald Duck"/></subject></DeviceAssociation></resource></entry><entry><fullUrl value="http://hl7.org/fhir/DeviceMetric/example-iv-pump-flowratemetric"/><resource><DeviceMetric><id value="example-iv-pump-flowratemetric"/><text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: DeviceMetric example-iv-pump-flowratemetric</b></p><a name="example-iv-pump-flowratemetric"> </a><a name="hcexample-iv-pump-flowratemetric"> </a><p><b>status</b>: Active</p><p><b>operationalStatus</b>: On</p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 157784}">MDC_FLOW_FLUID_PUMP</span></p><p><b>unit</b>: <span title="Codes:{http://unitsofmeasure.org mL/(8.h)}">mL/(8.h)</span></p><p><b>device</b>: <a href="broken-link.html">Device/example-IV-pump</a></p><p><b>category</b>: <span title="Codes:{http://hl7.org/fhir/metric-category measurement}">Measurement</span></p></div></text><status value="active"/><operationalStatus value="on"/><type><coding><system value="urn:iso:std:iso:11073:10101"/><code value="157784"/><display value="MDC_FLOW_FLUID_PUMP"/></coding></type><unit><coding><system value="http://unitsofmeasure.org"/><code value="mL/(8.h)"/><display value="mL/(8.h)"/></coding></unit><device><reference value="Device/example-IV-pump"/></device><category><coding><system value="http://hl7.org/fhir/metric-category"/><code value="measurement"/><display value="Measurement"/></coding></category></DeviceMetric></resource></entry></Bundle>